Technical specifications

PV String Input Date

ParameterST-6-8K-LV/AST-6-8K-LV/B
Max. PV Input Power(kW)912
Max. PV Input Voltage(V)800800
Start-up Voltage(V)250250
MPPT voltage range(V)200-700200-700
Rated PV Input voltage(V)500500
Max. Operating PV Input Current (A)20+2020+26
Max. Input Short Circuit Current (A)30+3030+39
No. of MPP Trackers/No. of Strings per MPP Tracker2/1+12/1+2

AC Output Side

ParameterST-6-8K-LV/AST-6-8K-LV/B
Rated AC Output Active Power(kW)68
Max. AC Output Apparent Power(kVA)68
Rated AC output current (A)15.8/15.121/20.1
Max. AC Output Current(A)15.8/15.121/20.1
Rated output voltage/range (V)127V/220V, 133V/230V 0.85UN-1.1UN127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form3L/N/PE3L/N/PE
Rated Output Grid Frequency/range(Hz)50/45-55, 60/55-6550/45-55, 60/55-65
Power Factor Adjustment Range0.8 leading to 0.8lagging0.8 leading to 0.8lagging
Total Current Harmonic Distortion THDi<3%<3%
DC Injection Current<0.5%ln<0.5%ln

Efficiency

ParameterST-6-8K-LV/AST-6-8K-LV/B
Max. Efficiency98.3%98.3%
Euro Efficiency97.8%98%
MPPT Efficiency>99%>99%

Equipment Protection

ParameterST-6-8K-LV/AST-6-8K-LV/B
DC Reverse Polarity ProtectionYesYes
AC Output Overcurrent ProtectionYesYes
AC Output Overvoltage ProtectionYesYes
AC Output Short Circuit ProtectionYesYes
Thermal ProtectionYesYes
Insulation Impedance DetectionYesYes
DC Component MonitoringYesYes
Arc Fault Circuit Interrupter (AFCI)OptionalOptional
Anti-islanding ProtectionYesYes
Residual Current DetectionYesYes
Surge Protection LevelTYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)
DC SwitchYesYes

Interface

ParameterST-6-8K-LV/AST-6-8K-LV/B
Communication InterfaceRS485/RS232 /WiFi/LANRS485/RS232 /WiFi/LAN
LCD/LED DisplayLCD1602LCD1602

General Data

ParameterST-6-8K-LV/AST-6-8K-LV/B
Operating Temperature Range (°C)-25 to -60℃-25 to -60℃
Permissible Ambient Humidity0~100%0~100%
Permissible Altitude (m)4000m4000m
Noise (dB)≤45≤45
Ingress Protection(IP) RatingIP 65IP 65
Inverter TopologyNon-IsolatedNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm)283×463×178 (Excluding Connectors and Brackets)283×463×178 (Excluding Connectors and Brackets)
Weight [kg]11.511.5
Warranty [year]5 years5 years
Type Of CoolingNatural CoolingNatural Cooling
Grid RegulationNBR 16149, NBR 16150, EN 50549, RD 140NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2