Deyeb DEYEB ST-33-50K-LV string inverters
← Back to catalogue

DEYEB ST-33-50K-LV

Grid-tie string inverter · 33–50 kW

String Inverters33–50 kW
Request a price

Technical specifications

PV String Input Date

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
Max. PV Input Power(kW)49.552.56067.575
Max. PV Input Voltage(V)800800800800800
Start-up Voltage(V)250250250250250
MPPT voltage range(V)200-700200-700200-700200-700200-700
Rated PV Input voltage(V)500500500500500
Max. Operating PV Input Current (A)40+40+40+4040+40+40+4040+40+40+4040+40+40+4040+40+40+40
Max. Input Short Circuit Current (A)60+60+60+6060+60+60+6060+60+60+6060+60+60+6060+60+60+60
No. of MPP Trackers/No. of Strings per MPP Tracker4/3+3+3+34/3+3+3+34/4+4+4+44/4+4+4+44/4+4+4+4

AC Input/Output Side

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
Rated AC Output Active Power(kW)3335404550
Max. AC Output Apparent Power(kVA)3335404550
Rated AC output current (A)86.7/82.891.9/87.8105/100.3118.2/112.8131.3/125.4
Max. AC Output Current(A)86.7/82.891.9/87.8105/100.3118.2/112.8131.3/125.4
Rated output voltage/range (V)127V/220V, 133V/230V 0.85UN-1.1UN127V/220V, 133V/230V 0.85UN-1.1UN127V/220V, 133V/230V 0.85UN-1.1UN127V/220V, 133V/230V 0.85UN-1.1UN127V/220V, 133V/230V 0.85UN-1.1UN
Grid Connection Form3L/N/PE3L/N/PE3L/N/PE3L/N/PE3L/N/PE
Rated Output Grid Frequency/range(Hz)50/45-55, 60/55-6550/45-55, 60/55-6550/45-55, 60/55-6550/45-55, 60/55-6550/45-55, 60/55-65
Power Factor Adjustment Range0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging
Total Current Harmonic Distortion THDi<3%<3%<3%<3%<3%
DC Injection Current<0.5%ln<0.5%ln<0.5%ln<0.5%ln<0.5%ln

Efficiency

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
Max. Efficiency98.6%98.6%98.70%98.70%98.70%
MPPT Efficiency>99%>99%>99%>99%>99%

Equipment Protection

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
DC Reverse Polarity ProtectionYesYesYesYesYes
AC Output Overcurrent ProtectionYesYesYesYesYes
AC Output Overvoltage ProtectionYesYesYesYesYes
AC Output Short Circuit ProtectionYesYesYesYesYes
Thermal ProtectionYesYesYesYesYes
Insulation Impedance DetectionYesYesYesYesYes
DC Component MonitoringYesYesYesYesYes
Arc Fault Circuit Interrupter (AFCI)OptionalOptionalOptionalOptionalOptional
Anti-islanding ProtectionYesYesYesYesYes
Residual Current DetectionYesYesYesYesYes
Surge Protection LevelTYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)
DC SwitchYesYesYesYesYes

Interface

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
Communication InterfaceRS485/RS232RS485/RS232RS485/RS232RS485/RS232RS485/RS232
Monitor ModeGPRS/WIFI/Bluetooth/4G/LAN(optional)GPRS/WIFI/Bluetooth/4G/LAN(optional)GPRS/WIFI/Bluetooth/4G/LAN(optional)GPRS/WIFI/Bluetooth/4G/LAN(optional)GPRS/WIFI/Bluetooth/4G/LAN(optional)

General Data

ParameterST-33-50K-LV/AST-33-50K-LV/BST-33-50K-LV/CST-33-50K-LV/DST-33-50K-LV/E
Operating Temperature Range (°C)-25 to +60℃, >45℃ Derating-25 to +60℃, >45℃ Derating-25 to +60℃, >45℃ Derating-25 to +60℃, >45℃ Derating-25 to +60℃, >45℃ Derating
Permissible Ambient Humidity0~100%0~100%0~100%0~100%0~100%
Permissible Altitude (m)4000m4000m4000m4000m4000m
Noise (dB)≤55 dB(A)≤55 dB(A)≤55 dB(A)≤55 dB(A)≤55 dB(A)
Ingress Protection(IP) RatingIP 65IP 65IP 65IP 65IP 65
Inverter TopologyNon-IsolatedNon-IsolatedNon-IsolatedNon-IsolatedNon-Isolated
Over Voltage CategoryOVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)
Cabinet Size (WxHxD mm)698×5613×236.5 (Excluding Connectors and Brackets)698×5613×236.5 (Excluding Connectors and Brackets)698×5613×236.5 (Excluding Connectors and Brackets)698×5613×236.5 (Excluding Connectors and Brackets)698×5613×236.5 (Excluding Connectors and Brackets)
Weight [kg]53.753.753.753.753.7
Warranty [year]5 years5 years5 years5 years5 years
Type Of CoolingIntelligent Air CoolingIntelligent Air CoolingIntelligent Air CoolingIntelligent Air CoolingIntelligent Air Cooling
Grid RegulationNBR 16149, NBR 16150, EN 50549, RD 140NBR 16149, NBR 16150, EN 50549, RD 140NBR 16149, NBR 16150, EN 50549, RD 140NBR 16149, NBR 16150, EN 50549, RD 140NBR 16149, NBR 16150, EN 50549, RD 140
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
Seguridad EMC/EstándarIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2