Deyeb DEYEB HB-3-6K-1P-D hybrid inverters
← Back to catalogue

DEYEB HB-3-6K-1P-D

Hybrid inverter · 3–6 kW · single phase

Hybrid Inverters3–6 kWSingle phase
Request a price

Technical specifications

Battery Input Data

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
Battery TypeLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ion
Battery Voltage Range(V)20-3040-6040-6040-6040-60
Max.Charging/Discharging Current(A)1407090120135
Charging Strategy for Li-ion BatterySelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMS
Number of battery input11111

PV String Input Data

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
Max. PV Access Power (W)6000600072001000012000
Max PV Input Power(W)48004800576080009600
Max PV Input Voltage(V)500500500500500
Start-up Voltage(V)125125125125125
MPPT Voltage Range(V)150-425150-425150-425150-425150-425
Rated PV Input Voltage(V)370370370370370
Max Operating PV Input Current(A)181818+1818+1818+18
Max Input Short-Circuit Current(A)272727+2727+2727+27
No.of MPP Trackers/No.of Strings MPP Tracker1/11/12/1+12/1+12/1+1

AC Input/Output Data

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
Rated AC Input/Output Active Power(W)36003600360050006000
Max AC Input/Output Apparent Power (VA)33003300396050006600
Rated AC Input/Output Current(A)13.6/1313.6/1316.4/15.722.7/21.727.3/26.1
Max AC Input/Output Current(A)15/14.315/14.318/17.2*25/23.930/28.7
Max Continuous AC Passthrough (grid to load)(A)3535353540
Peak Power (off-grid)(W)2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s
Power Factor Adjustment Range0.8 leading to 0.8lagging0.8 leading to 0.8lagging0.8 leading to 0.8lagging0.8 leading to 0.8lagging0.8 leading to 0.8lagging
Rated Input/Output Voltage/Range(V)220V/230V 0.85Un-1.1Un220V/230V 0.85Un-1.1Un220V/230V 0.85Un-1.1Un220V/230V 0.85Un-1.1Un220V/230V 0.85Un-1.1Un
Grid Connection FormL+N+PEL+N+PEL+N+PEL+N+PEL+N+PE
Rated Input/Output Grid Frequency/Range50Hz/45Hz-55Hz 60Hz/55Hz-65Hz50Hz/45Hz-55Hz 60Hz/55Hz-65Hz50Hz/45Hz-55Hz 60Hz/55Hz-65Hz50Hz/45Hz-55Hz 60Hz/55Hz-65Hz50Hz/45Hz-55Hz 60Hz/55Hz-65Hz
Total Current Harmonic Distortion THDi<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)
DC Injection Current<0.5%ln<0.5%ln<0.5%ln<0.5%ln<0.5%ln

Efficiency

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
Max Efficiency97.6%97.6%97.6%97.6%97.6%
Euro Efficiency96.5%96.5%96.5%96.5%96.5%
MPPT Efficiency>99%>99%>99%>99%>99%

Equipment Protection

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)

Interface

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
LCD/LED DisplayLCDLCDLCDLCDLCD
Communication InterfaceWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CAN

General Data

ParameterHB-3-6K-1P-D/AHB-3-6K-1P-D/BHB-3-6K-1P-D/CHB-3-6K-1P-D/DHB-3-6K-1P-D/E
Operating Temperature Range-40 to+60℃,>45℃ Derating-40 to+60℃,>45℃ Derating-40 to+60℃,>45℃ Derating-40 to+60℃,>45℃ Derating-40 to+60℃,>45℃ Derating
Permissible Ambient Humidity0~100%0~100%0~100%0~100%0~100%
Permissible Altitude2000m2000m2000m2000m2000m
Noise(dB)<30<30<30<30<30
Ingress Protection(IP) RatingIP 65IP 65IP 65IP 65IP 65
Inverter TopologyNon-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)
Over Voltage CategoryOVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm]330*433*228(Excluding connectors and brackets)330*433*228(Excluding connectors and brackets)330*433*228(Excluding connectors and brackets)330*433*228(Excluding connectors and brackets)330*433*228(Excluding connectors and brackets)
Weight[kg]1717171717
Warranty5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of CoolingNatural coolingNatural coolingNatural coolingNatural coolingIntelligent air cooling
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G98,G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2