Battery Input Data

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
Battery TypeLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ionLead-acid or Lithium-ion
Battery Voltage Range(V)40-6040-6040-6040-6040-6040-6040-60
Max.Charging/Discharging Current(A)90120135175190190210
Charging Strategy for Li-ion BatterySelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMSSelf-adaption to BMS
Number of Battery Input1111111

PV String Input Data

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
Max. PV Access Power (W)7200100001200014000152001600020000
Max. PV Input Power(W)57608000960011200121601280016000
Max. PV Input Voltage(V)500500500500500500500
Start-up Voltage(V)125125125125125125125
MPPT Voltage Range(V)150-425150-425150-425150-425150-425150-425150-425
Rated PV Input Voltage(V)370370370370370370370
Max. Operating PV Input Current(A)18+1818+1818+1832+3232+3232+3232+32
Max. Input Short-Circuit Current(A)27+2727+2727+2748+4848+4848+4848+48
No.of MPP Trackers/No.of Strings MPP Tracker2/1+12/1+12/1+12/2+22/2+22/2+22/2+2

AC Input/Output Data

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
Rated AC Input/Output Active Power(W)36005000600070007600800010000
Max. AC Input/Output Apparent Power (VA)39605500660077008360880011000
Rated AC Input/Output Current(A)16.4/15.722.7/21.727.3/26.131.9/30.534.5/3336.4/34.845.5/43.5
Max. AC Input/Output Current(A)18/17.225/23.930/28.735/33.538/36.340/38.350/47.9
Max. Continuous AC Passthrough (grid to load)(A)35354050505050
Peak Power (off-grid)(W)2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s2 times of rated power,10s
Rated Input/Output Voltage220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE220V/230V 0.85Un-1.1Un L+N+PE
Rated Input/Output Grid Frequency/Range(Hz)50/45-55,60/55-6550/45-55,60/55-6550/45-55,60/55-6550/45-55,60/55-6550/45-55,60/55-6550/45-55,60/55-6550/45-55,60/55-65
Power Factor Adjustment Range0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging0.8 leading-0.8lagging
Total Current Harmonic Distortion THDi<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)<3% (of nominal power)
DC Injection Current<0.5%ln<0.5%ln<0.5%ln<0.5%ln<0.5%ln<0.5%ln<0.5%ln

Efficiency

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
Max. Efficiency97.6%97.6%97.6%97.6%97.6%97.6%97.6%
Euro Efficiency96.5%96.5%96.5%96.5%96.5%96.5%96.5%
MPPT Efficiency>99%>99%>99%>99%>99%>99%>99%

Equipment Protection

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
IntegratedDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current DetectionDC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection
Surge Protection LevelTYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)TYPE II(DC),TYPE II(AC)

Interface

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
LCD/LED DisplayLCDLCDLCDLCDLCDLCDLCD
Communication InterfaceWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CANWIFI, RS485, CAN

General Data

ParameterHB-3.6-10K-1P/AHB-3.6-10K-1P/BHB-3.6-10K-1P/CHB-3.6-10K-1P/DHB-3.6-10K-1P/EHB-3.6-10K-1P/FHB-3.6-10K-1P/G
Operating Temperature Range-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating-40 to +60℃, >45℃ Derating
Permissible Ambient Humidity0~100%0~100%0~100%0~100%0~100%0~100%0~100%
Permissible Altitude2000m2000m2000m2000m2000m2000m2000m
Noise(dB)<45<45<45<45<45<45<45
Ingress Protection(IP) RatingIP 65IP 65IP 65IP 65IP 65IP 65IP 65
Inverter TopologyNon-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)Non-Isolated (solar), Isolated (battery)
Over Voltage CategoryOVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)OVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm]330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)330×580×232 (Excluding Connectors and Brackets)
Weight[kg]24.924.924.924.924.924.924.9
Warranty5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of CoolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air coolingIntelligent air cooling
Grid RegulationIEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105IEC 61727,IEC 62116,CEI 0-21,EN 50549,NRS 097,RD 140,UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105
Safety EMC/StandardIEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2