← Back to catalogue
DEYEB HB-3-12K-3P
Hybrid inverter · 3–12 kW · three phase
Hybrid Inverters3–12 kWThree phase
Request a priceTechnical specifications
Battery Input Data
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Battery Type | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion | Lead-acid or Lithium-ion |
| Battery Voltage Range (V) | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 | 40-60 |
| Max. Charging/Discharging Current (A) | 70 | 95 | 120 | 135 | 190 | 210 | 240 |
| Charging Strategy forLi-ion Battery | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS | Self-adaption to BMS |
| Number of Battery Input | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
PV String Input Data
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Max. PV Access Power (W) | 6000 | 8000 | 10000 | 12000 | 16000 | 20000 | 24000 |
| Max. PV Input Power (W) | 4500 | 6400 | 8000 | 9600 | 12800 | 16000 | 19200 |
| Max. PV Input Voltage (V) | 800 | 800 | 800 | 800 | 800 | 800 | 800 |
| Start-up Voltage (V) | 160 | 160 | 160 | 160 | 160 | 160 | 160 |
| MPPT Voltage Range (V) | 200-650 | 200-650 | 200-650 | 200-650 | 200-650 | 200-650 | 200-650 |
| Rated PV Input Voltage (V) | 550 | 550 | 550 | 550 | 550 | 550 | 550 |
| Max. Operating PV Input Current (A) | 20+20 | 20+20 | 20+20 | 20+20 | 20+20 | 26+26 | 26+26 |
| Max. Input Short-Circuit Current (A) | 30+30 | 30+30 | 30+30 | 30+30 | 30+30 | 39+39 | 39+39 |
| No. of MPP Trackers/No. of Strings MPP Tracker | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/1+1 | 2/2+2 | 2/2+2 |
AC Input/Output Data
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Rated AC Input/Output Active Power (W) | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 |
| Max. AC Input/Output Apparent Power (VA) | 3300 | 4400 | 5500 | 6600 | 8800 | 11000 | 13200 |
| Rated AC Input/Output Current (A) | 4.6/4.4 | 6.1/5.8 | 7.6/7.3 | 9.1/8.7 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 |
| Max. AC Input/Output Current (A) | 5/4.8 | 6.7/6.4 | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/16 | 20/19.2 |
| Max. Continuous AC Passthrough (grid to load) (A) | 45 | 45 | 45 | 45 | 45 | 45 | 45 |
| Peak Power (off-grid) (W) | 2 times of rated power, 10s | 2 times of rated power, 10s | 2 times of rated power, 10s | 2 times of rated power, 10s | 2 times of rated power, 10s | 2 times of rated power, 10s | 2 times of rated power, 10s |
| Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging | 0.8 leading to 0.8 lagging |
| Rated Input/Output Voltage | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE | 220/380V, 230/400V 0.85Un-1.1Un 3L+N+PE |
| Rated Input/Output Grid Frequency/Range(Hz) | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 | 50/45-55, 60/55-65 |
| Total Current Harmonic Distortion THDi | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) | <3% (of nominal power) |
| DC Injection Current | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In | <0.5% In |
Efficiency
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Max. Efficiency | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% | 97.6% |
| Euro Efficiency | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% | 97.0% |
| MPPT Efficiency | >99% | >99% | >99% | >99% | >99% | >99% | >99% |
Equipment Protection
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Integrated | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection | DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter (optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection, Residual Current Detection |
| Surge Protection Level | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) | TYPE II(DC),TYPE II(AC) |
Interface
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| LCD/LED Display | LCD | LCD | LCD | LCD | LCD | LCD | LCD |
| Communication Interface | WIFI,RS485,CAN | WIFI,RS485,CAN | WIFI,RS485,CAN | WIFI,RS485,CAN | WIFI,RS485,CAN | WIFI,RS485,CAN | WIFI,RS485,CAN |
General Data
| Parameter | HB-3-12K-3P/A | HB-3-12K-3P/B | HB-3-12K-3P/C | HB-3-12K-3P/D | HB-3-12K-3P/E | HB-3-12K-3P/F | HB-3-12K-3P/G |
|---|---|---|---|---|---|---|---|
| Operating Temperature Range (℃) | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating | -40 to +60℃, >45℃ Derating |
| Permissible Ambient Humidity | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% | 0-100% |
| Permissible Altitude | 3000m | 3000m | 3000m | 3000m | 3000m | 3000m | 3000m |
| Noise (dB) | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 | ≤55 |
| Ingress Protection(IP) Rating | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 | IP 65 |
| Inverter Topology | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) | Non-Isolated (solar), Isolated (battery) |
| Over Voltage Category | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) | OVC II(DC), OVC III(AC) |
| Cabinet Size (WxHxD mm) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) | 386×660×250 (Excluding Connectors and Brackets) |
| Weight (kg) | 35.2 | 35.2 | 35.2 | 35.2 | 35.2 | 35.2 | 35.2 |
| Type of Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling | Intelligent Air Cooling |
| Warranty | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | 5 Years/10 Yearsthe Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy |
| Grid Regulation | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 | IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,OVE-Richtlinie R25,G99,VDE-AR-N 4105 |
| Safety / EMC Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |